性做无码视频在线观看_国产精品爽爽ⅴa在线观看_婷婷丁香社区_亚洲av无码男人的天堂在线 无码人妻精品一区二区三区蜜桃_日本XXXX片免费观看

inner_banner

News classification

Product classification

Contact us

Shanghai Sales Centre:

Address: room 2406, greenbelt and Chuang building, 450 Cao Yang Road, Putuo District, Shanghai.

Mailbox: sales@jeffelcn.com

Tel: 021-62586212 0573-88222777

Fax: 021-62586271 0573-88222622

Website:   www.cqjjxc.com/en

What should you pay attention to when operating the membrane separation equipment?

Your current position: Home >> News >> Industry information

What should you pay attention to when operating the membrane separation equipment?

Date of release:2018-08-24 Author: Click:

1. Must use gloves


The staff of the ultrafiltration membrane manufacturer who operates the membrane separation equipment knows that it is necessary to wear the glove when using the membrane separation equipment. The effect is very good. On the contrary, if you do not wear this glove. After that, the problem will be quite serious.


Because the function of this glove is very powerful in this process, it can protect the hand from being rubbed. This is the minimum benefit. Others, for example, can be insulated, etc., needless to say, as long as you understand it. Therefore, when using the membrane separation equipment, it is necessary to bring the gloves on time and develop a very good habit. This is very helpful and can block many bad situations in time.


Membrane separation equipment worker

2. Adjust the air pressure


If you want to operate the membrane separation equipment very well, it is very targeted in controlling its air pressure, and it needs to be well controlled. This is a good operating procedure and it is very helpful for this equipment.


When adjusting the air pressure valve, it is necessary to pay attention to the fact that the valve should not be opened to the bottom at all times, which will cause the high air pressure to instantaneously hit the next air pressure zone through the valve. Such operation is very dangerous, and it is also a good for other valves. Excessive impact forces can easily cause blasting. Secondly, while the valve is slowly opening, observe the digital change of the barometer. When the pressure value of the new zone is too large, immediately close the gas valve, which can effectively protect each small gas pressure point in the membrane separation equipment. It can keep the dangerous series to a minimum, which is also a good operating specification.


The address of this article:http://www.cqjjxc.com/en/news/391.html

Key word:Operatingmembraneseparationequipment,Operatingmembraneseparationequipmentgloves,Membraneseparationequipmentregulatesairpressure

Recently Viewed:

relevant news:

relevant news::

.png

WeChat 2D code

Shanghai Sales Center:
icon1.png

Address:Room 2111, Greenland and Chuang Building,

No. 450 Caoyang Road, Putuo District, Shanghai

icon2.pngEmail: sales@jeffelcn.com
icon4.pngTel: 021-62586212
icon3.pngFax: 021-62586271
Zhejiang production base:
icon1.png

Add: No. 370, Century Avenue, Development

Zone, Chongfu Town, Tongxiang, Zhejiang, China

icon2.pngEmail: sales@jeffelcn.com
icon4.pngTel: 0573-88222777
icon3.pngFax: 0573-88222622


分享 一鍵分享
Please leave a message for us
Please input the message here, and we will contact you as soon as possible.
Full name
Contacts
Telephone
Seat / mobile phone number
mailbox
mailbox
address
address